Search:
  800-795-5111  

Other products by Middle Atlantic
(Website Link)



Item #: UPSS2200R
MSRP: No Retail
Login


MIDDLE ATLANTIC UPS-S2200R SELECT 2200/VA BACKUP POWER 1RU

 

Select Series UPS Backup power, 2RU, 2200VA

UPS-S2200R

Select Series UPS models are available in compact form factors when space is at a premium, and in a wide range of capacities to support a wide range of installations. All models are available with web-enabled IP control.

Features

  • Bank control of outlets for simple system reboot
  • Simulated sine wave output waveform
  • 8ms transfer time
  • Automatic Voltage Regulation
  • Non-critical load shedding
  • Surge protection and EMI filtering
  • LED status indicators
  • Battery pack easily replaced via front panel

General Info

Cable Type: Corded

Finish Type: Black

Surge Protected: Basic

Assembly/Installation Information

Mounting Points: 2

Listing Agencies/Third Party Information

RoHS: Yes

Greenguard: Yes

Dimensions

Mounting Depth Max: 32

Mounting Depth Min: 19

Depth: 16.5"

Height: 3.46"

Width: 19"

Primary Package Weight (US): 52.7

Rack Units: 2

Cord Information

Cord Length: 10'

Technical Information

Material: Steel

Mounting: Horizontal

Number of Outlets: 8

 

Select Series Rackmount Uninterruptible Power Supply (UPS) shall be Middle Atlantic Products model # UPS- S2000R. Rackmount UPS shall be AVR with boost only. Rackmount UPS shall measure 19.00” W x 3.46” H x 16.50” D and occupy 2 rackspaces. Rackmount UPS shall operate on 120 VAC/60Hz current. Rackmount UPS shall have a nominal output of 120V. Rackmount UPS shall have a capacity of 2000VA and 1320W. Rackmount UPS shall have (8) NEMA 5-20R receptacles on the rear of the unit. Rackmount UPS shall have a priority outlet bank consisting of 4x outlets dedicated to ensure maximum run time of critical components. Rackmount UPS shall have a non-critical outlet bank consisting of 4x outlets dedicated to load shedding. Rackmount UPS shall have a simulated sine wave output waveform. Rackmount UPS shall have an 8ms transfer time. Rackmount UPS shall be IP enabled when used with option IP Expansion card, model# UPS-IPCARD. Rackmount UPS shall include a 10’power cord with NEMA 5-20P plug. Rackmount UPS shall have surge suppression that utilizes a clean line-to-neutral design that does not pass noise contamination to ground. Rackmount UPS shall allow for a 13 minute run time at half load and a 4 minute run time at full load. Rackmount UPS shall be RoHS EU Directive 2002/95/ EC & 2011/65/EU compliant. Rackmount UPS shall utilize Middle Atlantic Power Managerâ„¢ software. Rackmount UPS shall be warrantied to be free from defects in materials and workmanship under normal use and conditions for a period of 3 years; battery shall be warrantied for a period of 2 years. Rackmount UPS shall be UL listed in US and Canada.



New Project

Volutone