MIDDLE ATLANTIC UPS-1000R PREMIUM BACKUP POWER SYSTEMS
Premium Series UPSRackmount Power, 8 Outlet, 1000VA/750W
Features
- Line Interactive UPS technology for quiet operation and energy savings
- Fast 4 millisecond transfer time (1/4 cycle) for no system disruption or lockups
- Pure Sine Wave technology provides the cleanest power for sensitive devices
- Automatic Voltage Regulation ensures stable 120VAC output
- Hot swappable battery for easy service with front panel access
General Info
Cable Type: Corded
Finish Type: Black
UL Standards Tested: 1778
Termination: 5-15P
Surge Protected: Basic
Assembly/Installation Information
Mounting Points: 4
Listing Agencies/Third Party Information
RoHS: Yes
Greenguard: Yes
UL Listing No: E325394
Dimensions
Mounting Depth Max: 32
Mounting Depth Min: 19
Depth: 20"
Height: 3.47"
Width: 19"
Primary Package Weight (US): 76
Rack Units: 2
Cord Information
Cord Length: 9'
Technical Information
Amps: 15
Material: Steel
Mounting: Horizontal
Volts: 120
Number of Circuits: 1
Number of Outlets: 8
Premium Rackmount Uninterruptible Power Supply (UPS) shall be Middle Atlantic Products model # UPS-1000R. UPS shall be line interactive with AVR. Unit shall measure 19.00” W x 3.50” H x 19.00” D and occupy 2 rackspaces. UPS shall have a rear mounting range of 19” to 32” and not require more than one person to mount. Unit shall operate on 120 VAC/60Hz current. Unit shall have a nominal output of 120V. Unit shall have a capacity of 1000 VA and 750 W. Unit shall have (8) NEMA 5-15R receptacles on the rear of the unit. Unit shall have a priority outlet bank consisting of 4 outlets dedicated to ensure maximum run time of critical components. Unit shall have a non-critical outlet bank consisting of 4 outlets dedicated to load shedding. Unit shall be IP enabled when used with optional IP Expansion card, model# UPS-IPCARD. Rackmount UPS shall include a 9’ 14/3 SignalSAFEâ„¢ power cord with NEMA 5-15P plug. UPS shall have surge suppression that utilizes a clean line-to-neutral design that does not pass noise contamination to ground. Rackmount UPS shall have a hot swappable battery that allows for a 26 minute run time at half load and a 13 minute run time at full load. Rear of unit shall have inputs that allow for the installation of up to 10 additional hot swappable batteries. Rackmount UPS shall be RoHS EU Directive 2002/95/EC compliant. Rackmount UPS shall utilize Middle Atlantic Power Managerâ„¢ software. Rackmount UPS shall be warrantied to be free from defects in materials and workmanship under normal use and conditions for a period of 3 years; battery shall be warrantied for a period of 2 years. Rackmount UPS shall be UL listed in US and Canada.
 | Loading… |
|